HVAC Service Technician Job Description

HVAC & Mechanical

Diagnoses and repairs commercial rooftop units, split systems, chillers, and the controls wrapped around them, usually working alone and usually on a schedule the building sets. The work divides roughly in half between diagnosis and customer handling, because the service technician is the only person from the contractor the building ever sees. Covers scheduled maintenance, demand calls, warranty work, and the documentation that turns a repair into an approved invoice.

15essential duties
8 / 7required / preferred qualifications
6credentials, each with who verifies it
Take this away as a Word document The same description, formatted for a personnel file, with an acknowledgement signature block at the end. The first download asks for your name, company, work email and phone; after that every document here downloads without a form.
Download .docx

What this seat pays

$48,000 to $72,000 My Trade Talent band

My Trade Talent mid-experience band, built from our own engagement history. Experience and region move it; the salary calculator applies both.

Pay, location and the date prepared are blank in the Word version on purpose. They depend on your market and your margins, and a template that guesses at them is worse than one that leaves them to you. The figure above is here so the guess is at least anchored.

The seat

Reports toService Manager
Direct reportsNone (may direct an apprentice or helper)
FLSA statusNon-exempt — confirm with counsel
TradeHVAC & Mechanical
Pay band$48,000 to $72,000 — My Trade Talent band

Where the role goes next. Strong service technicians move to lead tech, then service manager, or sideways into controls, which usually pays better sooner.

Essential duties (15)

  • Diagnose no-cooling, no-heat, and short-cycling calls on packaged rooftop units, split systems, and heat pumps using gauge readings, superheat and subcooling, and amp draw rather than parts swapping.
  • Recover, evacuate, weigh in, and document refrigerant charge in accordance with EPA Section 608 requirements on every system opened.
  • Troubleshoot low-voltage control circuits, contactors, relays, transformers, pressure and limit switches, and board-level faults with a meter and the wiring diagram.
  • Service gas heat sections: inspect heat exchangers, clean and set burners, verify manifold pressure, test ignition controls and flame sensing, and check flue and combustion air.
  • Perform scheduled preventive maintenance on belts, bearings, filters, coils, drain pans and condensate lines, economizers, and damper linkage.
  • Work on chilled water and hot water systems including pumps, coils, valves, and strainers, and log entering and leaving water temperatures.
  • Interface with building automation and packaged unit controllers to read fault history, verify sensor calibration, and confirm setpoints and schedules after a repair.
  • Braze, swage, and pressure-test refrigerant piping, and pull a deep vacuum with a micron gauge before charging.
  • Replace compressors, motors, blower assemblies, VFDs, and coils, including rigging and hoisting on roof-mounted equipment.
  • Write a service ticket on every call recording the complaint, the cause, the correction, readings taken, parts used, and recommended follow-up work.
  • Quote needed repairs and replacement options to the building contact and flag equipment at end of life for the account manager.
  • Keep the service van stocked, organized, and clean, maintain the tool inventory, and return cores and unused parts to the shop.
  • Protect the customer's property with drop cloths in finished spaces, ladder pads, and removal of all packaging and old parts from the site.
  • Submit timesheets, purchase receipts, and mileage daily so labor and material hit the correct work order.
  • Take rotating after-hours and weekend on-call duty and respond within the dispatch window.

Qualifications

Required
  • Three or more years of commercial HVAC service experience diagnosing and repairing packaged rooftop units and split systems without supervision.
  • EPA Section 608 Universal certification.
  • Valid driver's license with a motor vehicle record acceptable to the company's insurance carrier.
  • Ability to read wiring diagrams, piping schematics, and equipment service literature.
  • Ability to work from ladders and on roofs up to 40 feet and to lift 50 pounds from the ground to waist height.
  • Own hand tools, gauges, and meters as listed on the company tool list.
  • Availability for rotating on-call and for occasional night and weekend work in occupied buildings.
  • Ability to pass a pre-employment drug screen and the background check customer sites require.
Preferred
  • Experience with air-cooled and water-cooled chillers, including compressor teardown and oil analysis.
  • Working familiarity with at least one building automation front end such as Metasys, Niagara, or Tracer.
  • Factory training on one or more major equipment lines such as Carrier, Trane, York, Daikin, or Lennox.
  • State journeyman or mechanical license where the jurisdiction issues one.
  • NATE certification in air conditioning, heat pumps, or commercial refrigeration.
  • Experience with VRF systems and with hydronic balancing and startup.
  • Ability to write a legible quote on site and sell a repair to a non-technical building contact.

The line between these two columns is the one that costs you candidates. Everything in the preferred column that gets written into a posting as a requirement removes people who could do the job, and in a trade with a shortage that is a self-inflicted wound.

Credentials, and who verifies them

CredentialStatusVerify with
EPA Section 608 UniversalRequiredCopy of card on file, verified with the issuing certifying organization
Driver's license and acceptable MVRRequiredAnnual MVR pull through the company's insurance carrier
State journeyman or HVAC mechanical licenseWhere the state requires itState licensing board online lookup
NATE certificationPreferredNATE certified technician verification lookup
OSHA 10 or OSHA 30 constructionPreferredCourse completion card and the training provider's record
Manufacturer factory training certificatesPreferredCertificates from the manufacturer's training portal

Verify before an offer rather than after. A credential taken on trust at offer is the most expensive line on this page. We track HVAC & mechanical licensing in 38 states; which of them applies depends on where the work is, not where the company is.

Physical demands

ActivityFrequency
Climbing fixed ladders, extension ladders, and roof hatchesFrequent (1/3 to 2/3 of shift)
Working at heights on open rooftops near unguarded edges and skylightsFrequent (1/3 to 2/3 of shift)
Standing and walking on gravel, membrane, and sloped roof surfacesConstant (over 2/3 of shift)
Kneeling, squatting, and lying prone to reach blower compartments and pipingFrequent (1/3 to 2/3 of shift)
Lifting and carrying up to 50 pounds of tools, motors, and partsFrequent (1/3 to 2/3 of shift)
Lifting over 75 pounds with assistance or mechanical aid, such as a compressorOccasional (under 1/3 of shift)
Reaching overhead and working with arms above shoulder heightFrequent (1/3 to 2/3 of shift)
Exposure to outdoor heat, cold, wind, and sun for extended periodsConstant (over 2/3 of shift)
Working in confined or restricted spaces such as mechanical rooms, attics, and crawl spacesOccasional (under 1/3 of shift)
Exposure to brazing fumes, refrigerant under pressure, and electrical energy up to 480 voltsOccasional (under 1/3 of shift)
Half-face respirator or N95 use for coil cleaning chemicals and dusty filter changesOccasional (under 1/3 of shift)
Driving a service vehicle between sitesFrequent (1/3 to 2/3 of shift)

This is the section a reasonable accommodation decision actually turns on, which is why it is role specific rather than copied across a trade. An estimator sits and walks sites; a screed operator stands beside hot asphalt all day.

Work environment

Work happens on commercial rooftops, in mechanical rooms, above ceilings, and in occupied tenant spaces, year round and in whatever weather the call falls on. Hazards include roof edges and skylights, energized equipment up to 480 volts, rotating belts and fans, hot brazing work, refrigerant under pressure, and ladder access. Noise in fan rooms often requires hearing protection. Many calls fall in occupied buildings during business hours, and some fall after hours.

Tools and equipment

The company provides the service vehicle, fuel card, recovery machine, vacuum pump, micron gauge, combustion analyzer, specialty gauges, power tools, ladders, fall protection, and a tablet or phone with the dispatch and ticketing application. The technician owns hand tools, a digital manifold or gauge set, multimeter, clamp meter, refrigeration wrenches, nut drivers, flashlights, and work boots.

How performance is measured

MeasureWhat it captures
Callback ratePercentage of repairs that bring a technician back for the same complaint within 30 days
First-visit completionShare of demand calls resolved on the first trip without a return for parts or further diagnosis
Billable hour utilizationHours charged to a work order as a percentage of hours paid
Ticket quality and completenessTickets that carry complaint, cause, correction, readings, and parts without the office having to call back
Quoted work generated and convertedDollar value of repair and replacement recommendations written and the share the customer approves
Preventive maintenance task completionPM visits completed on schedule with every checklist line filled and deficiencies reported
Safety recordRecordable incidents, vehicle incidents, and documented fall protection and lockout compliance

These are the same measures the annual review for this role is built on, so the document you hire against and the document you rate against are measuring one thing.

Reading a resume for this seat

What separates a strong HVAC Service Technician from a plausible one, on paper and in the first ten minutes of a call:

  • Talks in symptoms and causes rather than part numbers - superheat and subcooling readings, not "I replaced the TXV"
  • Has worked unaccompanied on rooftop equipment, not just assisted on installs
  • Can describe a call they diagnosed wrong and what the second visit found

Screen for it: 3 questions and what a strong answer contains

A job description tells you what you need. These tell you whether the person in front of you has it. Each one comes with what a strong answer contains, because an interviewer who does not know that is persuaded by fluency, which is exactly what the question was supposed to see past.

Walk me through diagnosing a rooftop unit that cools fine in the morning and short-cycles by two in the afternoon.

What a strong answer contains

Treats it as load and ambient dependent rather than random, and separates refrigeration causes (high head on a dirty or recirculating condenser, a failing condenser fan, overcharge, non-condensables) from control causes (a thermostat or sensor seeing the wrong thing, a safety cutting out and resetting). Says they would go back when it actually faults, or load it, and take readings while it is faulting rather than diagnosing it cold in the morning.

Follow up with: What readings do you take while it is short-cycling, and what would tell you it is a control problem rather than a refrigeration one?

What superheat would you expect on a properly charged R-410A system, and what does it tell you when it reads high?

What a strong answer contains

Asks about the metering device before giving a number, because the answer differs: a TXV system holds a fairly narrow evaporator superheat, a fixed-orifice system is charged off the manufacturer chart against indoor wet bulb and outdoor dry bulb. Reads high superheat as a starved evaporator and lists undercharge, a restriction, or a TXV underfeeding as the places to look.

Follow up with: What do you need to know about the metering device before that number means anything?

A tenant says it is too warm and the space is at setpoint. What do you check and in what order?

What a strong answer contains

Goes to the space before the equipment. Where the thermostat is compared with where the person sits, whether the sensor is in sun or over a heat source, diffuser throw and whether it is blowing on someone or past them, solar and equipment load in that corner, the VAV box or zone damper, and whether the space was ever balanced for its current use.

Follow up with: How do you handle it when the equipment is working correctly and the tenant is still uncomfortable?

The mistake this seat invites

Hiring on EPA 608 and years of experience without testing diagnostic reasoning. The certification is a floor, not a signal, and residential-heavy experience transfers badly to rooftop and chiller work.

How long this takes to fill

My Trade Talent's median HVAC & mechanical hire took 15 days across 36 searches closed in 2026 year to date, counted as calendar days from our first contact with the candidate to the hire.

Worth writing on the requisition before you post it. The cost of the vacancy runs from the day the seat empties, not from the day you start looking, and the calculator will put a number on it for your billing rate.

Questions employers ask about this role

What does an HVAC Service Technician do?

Diagnoses and repairs commercial rooftop units, split systems, chillers, and the controls wrapped around them, usually working alone and usually on a schedule the building sets. The work divides roughly in half between diagnosis and customer handling, because the service technician is the only person from the contractor the building ever sees. Covers scheduled maintenance, demand calls, warranty work, and the documentation that turns a repair into an approved invoice. The full description below lists 15 essential duties in trade terms, with physical demands and frequencies.

What qualifications does an HVAC Service Technician need?

8 requirements are written as non-negotiable for this seat. The first 3: Three or more years of commercial HVAC service experience diagnosing and repairing packaged rooftop units and split systems without supervision; EPA Section 608 Universal certification; Valid driver's license with a motor vehicle record acceptable to the company's insurance carrier. A further 7 qualifications are preferred rather than required, which is the distinction that decides whether a good candidate gets screened out by your own posting.

What credentials should I verify before making an offer to an HVAC Service Technician?

3 credentials on this role are either required outright or required where the state requires it: EPA Section 608 Universal, Driver's license and acceptable MVR and State journeyman or HVAC mechanical license. Each one has a named place to verify it in the table below. Verify before the offer rather than after; a credential taken on trust at offer is the most expensive line in a job description.

Is an HVAC Service Technician exempt or non-exempt?

Non-exempt — confirm with counsel. FLSA status turns on the duties actually performed rather than the job title, and the duties for this seat are listed below so a classification decision has something to rest on. We are not lawyers and the note here is a starting point for counsel, not a determination.

What should an HVAC Service Technician be paid?

$48,000 to $72,000. My Trade Talent mid-experience band, built from our own engagement history. Experience and region move it; the salary calculator applies both.

How long does it take to hire an HVAC Service Technician?

My Trade Talent's median HVAC & mechanical hire took 15 days across 36 searches closed in 2026 year to date, counted as calendar days from our first contact with the candidate to the hire.

What is the most common hiring mistake in this seat?

Hiring on EPA 608 and years of experience without testing diagnostic reasoning. The certification is a floor, not a signal, and residential-heavy experience transfers badly to rooftop and chiller work.

Trade Talk A monthly hiring brief for commercial trades employers

What changed in your trade this month, and what to do about it.

One email a month, and only one. We write a separate issue for every trade we recruit in, so you get yours - not a round-up with your trade buried in paragraph nine. Every issue is written for the person actually doing the hiring.

  • Where wages moved in your trade, by market, and what that does to your next offer
  • How long roles like yours are taking to fill, and where it is getting worse
  • Interview and screening tactics that are landing candidates this month
  • What contractors competing for the same people are doing differently

Built on federal wage data, our own closed searches, and what we hear on the desk every week. Written for employers, not candidates. No pitch, no filler, one click to leave.

Pick your trade. That is the one issue you get, once a month.

One email a month. Your trade and your address, nothing else - we do not sell either, and you can unsubscribe from the bottom of any issue. Read this month's issue for your trade first →