Journeyman Electrician (Commercial) Job Description
Commercial Electrical
The Journeyman Electrician installs and troubleshoots commercial power and lighting under a state or local license. The work covers branch circuits, panels, feeders, conduit systems, gear and the terminations that connect them. The journeyman reads the drawings, lays out the work in the field, installs it to code and to the specification, and on most jobs directs an apprentice while answering to the foreman for daily production.
What this seat pays
My Trade Talent mid-experience band, built from our own engagement history. Experience and region move it; the salary calculator applies both.
Pay, location and the date prepared are blank in the Word version on purpose. They depend on your market and your margins, and a template that guesses at them is worse than one that leaves them to you. The figure above is here so the guess is at least anchored.
The seat
| Reports to | Electrical Foreman |
| Direct reports | None (typically directs one apprentice) |
| FLSA status | Non-exempt — confirm with counsel |
| Trade | Commercial Electrical |
| Pay band | $58,000 to $88,000 — My Trade Talent band |
Where the role goes next. Journeymen progress to foreman, then general foreman or master electrician, with the licence being the gate on the second path.
Essential duties (15)
- Lay out branch circuit and lighting work from the drawings, using dimensions, column lines and ceiling grid rather than scaling off the print.
- Install EMT, rigid, IMC and PVC conduit systems, bending offsets, saddles and kicks by hand and with mechanical and hydraulic benders.
- Install cable tray, strut, hangers and supports at the spacing the code and the specification require, and seismically brace where the drawings call for it.
- Pull branch circuits and feeders, calculate conductor fill and pull tension, and lubricate and rope long pulls without damaging insulation.
- Terminate devices, panels, disconnects and transformer secondaries, torquing lugs and breakers to the manufacturer's stated values and documenting the values used.
- Set panelboards, transformers, disconnects and motor control equipment plumb and level with the required working clearances maintained.
- Install and connect lighting fixtures, emergency and exit lighting, occupancy sensors, dimming controls and lighting control panels, and verify the control sequence works as designed.
- Make up boxes, install devices and trim out tenant and core spaces to a finish standard that passes the architect's punch walk.
- Install and connect motor circuits, VFDs, equipment hookups and controls from mechanical and equipment schedules, coordinating disconnect locations with the installing trade.
- Troubleshoot energized and de-energized circuits with a multimeter, clamp meter, insulation resistance tester and phase rotation meter, and isolate faults without guessing.
- Apply lockout and tagout, verify the absence of voltage before working, and wear the arc flash PPE the task's incident energy requires.
- Install and maintain temporary power and lighting, including GFCI protection and assured grounding inspections.
- Coordinate routing in the ceiling and in congested walls with mechanical, fire protection and framing crews before installing, and raise conflicts to the foreman instead of installing into them.
- Direct, instruct and check the work of an assigned apprentice, and keep that apprentice productive and safe through the day.
- Complete daily timesheets with correct cost codes, submit material requisitions ahead of need, mark up field drawings for as-builts, and leave the work area swept and free of scrap at the end of each shift.
Qualifications
- Current journeyman electrician license in the state or local jurisdiction where the work is performed
- Completion of a recognized electrical apprenticeship, or four years of documented commercial electrical experience with the required hours for licensure
- Ability to read commercial electrical drawings, one-line diagrams, panel schedules and specifications and install directly from them
- Working knowledge of the current National Electrical Code edition adopted in the jurisdiction
- Ability to bend conduit accurately by hand and with mechanical and hydraulic benders
- Ability to lift 50 pounds repeatedly, work from ladders and aerial lifts, and work in trenches, attics and mechanical rooms
- Valid driver's license and reliable transportation to job sites
- OSHA 10-hour Construction card or willingness to obtain one before starting field work
- OSHA 30-hour Construction card
- Scissor lift and boom lift operator certification
- NFPA 70E arc flash training within the last three years
- Experience in healthcare, data center, industrial or other inspected high-specification environments
- Fire alarm, security, structured cabling or building control low-voltage experience
- Experience installing and terminating medium-voltage or large switchgear under supervision
- Current first aid and CPR certification
The line between these two columns is the one that costs you candidates. Everything in the preferred column that gets written into a posting as a requirement removes people who could do the job, and in a trade with a shortage that is a self-inflicted wound.
Credentials, and who verifies them
| Credential | Status | Verify with |
|---|---|---|
| State or local journeyman electrician license | Required | State or municipal electrical licensing board |
| OSHA 10-hour Construction | Required | Card number and authorized trainer |
| OSHA 30-hour Construction | Preferred | Card number and authorized trainer |
| NFPA 70E arc flash training | Where the state requires it | Training provider certificate and date |
| Aerial and scissor lift operator certification | Preferred | Employer training record or equipment dealer |
| Valid driver's license | Required | State motor vehicle record check |
Verify before an offer rather than after. A credential taken on trust at offer is the most expensive line on this page. We track commercial electrical licensing in 39 states; which of them applies depends on where the work is, not where the company is.
Physical demands
| Activity | Frequency |
|---|---|
| Standing and walking on concrete, decking and uneven ground | Constant (over 2/3 of shift) |
| Gripping, pinching and fine hand work for terminations and device makeup | Constant (over 2/3 of shift) |
| Distinguishing conductor and tracer colors for circuit identification | Constant (over 2/3 of shift) |
| Reaching and working with arms above shoulder height for overhead conduit and fixtures | Frequent (1/3 to 2/3 of shift) |
| Climbing ladders and stair towers | Frequent (1/3 to 2/3 of shift) |
| Working from a scissor lift or boom lift above six feet | Frequent (1/3 to 2/3 of shift) |
| Bending, stooping, kneeling and squatting to install boxes and pull wire | Frequent (1/3 to 2/3 of shift) |
| Lifting and carrying up to 50 pounds, such as conduit bundles and fixture cartons | Frequent (1/3 to 2/3 of shift) |
| Pushing and pulling with force during wire pulls and equipment setting | Frequent (1/3 to 2/3 of shift) |
| Team lifting over 75 pounds, such as panelboards and transformers | Occasional (under 1/3 of shift) |
| Crawling or working in trenches, attics, crawl spaces and confined spaces | Occasional (under 1/3 of shift) |
| Driving a company or personal vehicle between sites | Occasional (under 1/3 of shift) |
This is the section a reasonable accommodation decision actually turns on, which is why it is role specific rather than copied across a trade. An estimator sits and walks sites; a screed operator stands beside hot asphalt all day.
Work environment
Work happens on active commercial construction sites and in occupied buildings: open decking, unconditioned shells, mechanical rooms, ceiling spaces, electrical rooms, trenches and roofs. Conditions include concrete dust, noise, vibration, welding and cutting nearby, heat and cold, and overhead work from lifts and ladders. Energized equipment is present on service and renovation work. Night, weekend and shutdown shifts occur when tie-ins cannot happen during business hours.
Tools and equipment
The employer provides conduit benders, threaders, cable pullers, hydraulic knockouts, lifts, cordless and hammer drills, test instruments, arc flash PPE, hard hat, safety glasses, gloves and all material. The electrician is expected to own a complete hand tool set with pliers, strippers, drivers, nut drivers, levels, tape, hacksaw, hand bender, tool bags and work boots, and to keep them serviceable.
How performance is measured
| Measure | What it captures |
|---|---|
| Installed quantity against estimated hours | Devices, fixtures, footage of conduit and wire installed per hour compared with the labor budget for that cost code |
| First-time inspection pass rate | Rough and final inspections on the electrician's work that pass without correction notices |
| Rework hours | Hours charged to correcting the electrician's own installed work, including code and torque corrections |
| Punch list items | Count of punch items attributed to the electrician's installation at project turnover |
| Recordable and near-miss incidents | Injuries, near misses and safety observations tied to the electrician's work area |
| Apprentice productivity | Whether the assigned apprentice is engaged in productive, instructed work through the shift |
| Timesheet and requisition accuracy | Daily hours coded to the correct cost code and material requested before it stops the work |
These are the same measures the annual review for this role is built on, so the document you hire against and the document you rate against are measuring one thing.
Reading a resume for this seat
What separates a strong Journeyman Electrician (Commercial) from a plausible one, on paper and in the first ten minutes of a call:
- Conduit bending described as routine - offsets, saddles, large-diameter rigid
- Has worked live-adjacent under NFPA 70E and can describe the boundary rules
- Commercial and industrial service sizes rather than residential panel swaps
Screen for it: 3 questions and what a strong answer contains
A job description tells you what you need. These tell you whether the person in front of you has it. Each one comes with what a strong answer contains, because an interviewer who does not know that is persuaded by fluency, which is exactly what the question was supposed to see past.
How do you size a feeder for a 200A three-phase panel, and what in the code drives it?
What a strong answer containsStarts from the calculated load rather than the panel rating, then conductor ampacity with ambient correction and adjustment for current-carrying conductors in the raceway, limited by the termination temperature rating at both ends - which is the step most people skip. Then overcurrent protection, the equipment grounding conductor, and voltage drop on a long run. Naming the chain matters more than reciting article numbers.
Follow up with: Why can the right conductor still be the wrong one once you look at the lugs?
Walk me through your lockout-tagout sequence on a 480V panel.
What a strong answer containsNotify who is affected, identify every source rather than the obvious one, shut down in order, open the disconnect, their own lock and their own tag, release stored energy including a VFD DC bus, then verify dead with a correctly rated meter proved on a known live source before and after. Treats the verification itself as energised work and dresses for it.
Follow up with: What stored energy is still in that panel after you open the disconnect?
What is the difference in how you treat a grounded conductor and an equipment grounding conductor on a sub-panel?
What a strong answer containsBonded together only at the service. At a sub-panel the neutral sits on an isolated bar, the grounding conductors on a bonded bar, and the bonding screw or strap comes out. Can say why rather than just what: bonding them downstream puts normal neutral current onto the grounding conductor and the raceway, which is a shock path and a nuisance-trip source.
Follow up with: What goes wrong in the building if someone leaves the bonding screw in?
The mistake this seat invites
Taking a state licence as proof of commercial capability. Licensing rules vary by state and many journeyman licences are earned on residential hours.
How long this takes to fill
My Trade Talent's median commercial electrical hire took 30 days across 11 searches closed in 2026 year to date, counted as calendar days from our first contact with the candidate to the hire.
Worth writing on the requisition before you post it. The cost of the vacancy runs from the day the seat empties, not from the day you start looking, and the calculator will put a number on it for your billing rate.
Questions employers ask about this role
What does a Journeyman Electrician (Commercial) do?
The Journeyman Electrician installs and troubleshoots commercial power and lighting under a state or local license. The work covers branch circuits, panels, feeders, conduit systems, gear and the terminations that connect them. The journeyman reads the drawings, lays out the work in the field, installs it to code and to the specification, and on most jobs directs an apprentice while answering to the foreman for daily production. The full description below lists 15 essential duties in trade terms, with physical demands and frequencies.
What qualifications does a Journeyman Electrician (Commercial) need?
8 requirements are written as non-negotiable for this seat. The first 3: Current journeyman electrician license in the state or local jurisdiction where the work is performed; Completion of a recognized electrical apprenticeship, or four years of documented commercial electrical experience with the required hours for licensure; Ability to read commercial electrical drawings, one-line diagrams, panel schedules and specifications and install directly from them. A further 7 qualifications are preferred rather than required, which is the distinction that decides whether a good candidate gets screened out by your own posting.
What credentials should I verify before making an offer to a Journeyman Electrician (Commercial)?
4 credentials on this role are either required outright or required where the state requires it: State or local journeyman electrician license, OSHA 10-hour Construction, NFPA 70E arc flash training and Valid driver's license. Each one has a named place to verify it in the table below. Verify before the offer rather than after; a credential taken on trust at offer is the most expensive line in a job description.
Is a Journeyman Electrician (Commercial) exempt or non-exempt?
Non-exempt — confirm with counsel. FLSA status turns on the duties actually performed rather than the job title, and the duties for this seat are listed below so a classification decision has something to rest on. We are not lawyers and the note here is a starting point for counsel, not a determination.
What should a Journeyman Electrician (Commercial) be paid?
$58,000 to $88,000. My Trade Talent mid-experience band, built from our own engagement history. Experience and region move it; the salary calculator applies both.
How long does it take to hire a Journeyman Electrician (Commercial)?
My Trade Talent's median commercial electrical hire took 30 days across 11 searches closed in 2026 year to date, counted as calendar days from our first contact with the candidate to the hire.
What is the most common hiring mistake in this seat?
Taking a state licence as proof of commercial capability. Licensing rules vary by state and many journeyman licences are earned on residential hours.
One time
Where should we send it?
Tell us who you are once and every document on this site downloads for you from then on, with no form in the way. We are a recruiting firm: someone may call about the roles you are hiring for.