Skip to main content
Job description

Electrician (LED & Solar) Job Description

LED & Solar

Performs the licensed electrical work on commercial lighting retrofit and solar projects: service and panel work, conductor sizing and raceway runs, inverter and disconnect installation, utility interconnection, and the control and sensor work that makes a lighting job meet its specification. This seat also carries the end of the job, meaning testing, commissioning, the inspection walkthrough and the utility or rebate sign-off, which is where the paperwork and the payment both live.

15essential duties
8 / 7required / preferred qualifications
6credentials, each with who verifies it
Take this away as a Word document The same description, formatted for a personnel file, with an acknowledgement signature block at the end. The first download asks for your name, company, work email and phone; after that every document here downloads without a form.
Download .docx

What this seat pays

$42,640 to $108,510 BLS 10th to 90th percentile

Federal figures: BLS Occupational Employment and Wage Statistics, May 2025, national, SOC 47-2111. The range is the 10th to 90th percentile and the median is $63,190. It is not adjusted for experience or region, and it is not a My Trade Talent band.

Pay, location and the date prepared are blank in the Word version on purpose. They depend on your market and your margins, and a template that guesses at them is worse than one that leaves them to you. The figure above is here so the guess is at least anchored.

The seat

Reports toElectrical Foreman or Project Manager
Direct reportsNone (may direct an apprentice or electrical helper)
FLSA statusNon-exempt — confirm with counsel
TradeLED & Solar
Pay band$42,640 to $108,510 — BLS 10th to 90th percentile

Where the role goes next. Electricians on this work move to foreman or project manager, and NABCEP certification raises their standing on solar jobs.

Essential duties (15)

  • Performs service, switchgear and panel work on retrofit and PV projects, including breaker and lug installation, panel schedule updates and load calculations.
  • Sizes conductors, overcurrent protection and grounding for the circuit, the ambient conditions and the conduit fill, and documents the basis of the decision.
  • Installs raceway including EMT, rigid, PVC and cable tray with correct supports, bends, expansion fittings and firestopping at rated assemblies.
  • Pulls, terminates and torques conductors to manufacturer values, labels circuits, and lands work so the next electrician can follow it.
  • Installs and wires string and central inverters, AC and DC disconnects, rapid shutdown equipment, production metering and the AC combiner.
  • Makes the utility interconnection, supply side or load side, including the tap, metering and labeling, and stands for the utility witness inspection.
  • Installs lighting controls including occupancy and daylight sensors, zero to ten volt and digital dimming, relay panels and networked systems, and programs them to the sequence of operations.
  • Retrofits and replaces fixtures and drivers on occupied sites, verifying voltage, removing or bypassing ballasts correctly and confirming compatibility with existing controls.
  • Performs lockout and tagout and energized work risk assessment, establishes boundaries, and tests for absence of voltage before contact.
  • Troubleshoots with a meter and a clamp for open and shared neutrals, ground faults, voltage drop and dimming circuit noise, rather than swapping parts.
  • Commissions the installed system with a functional test of every control zone, inverter startup, production verification and a written test and punch record.
  • Walks the inspection with the authority having jurisdiction, corrects noted items, and assembles the closeout package of as-builts, test results, serial numbers and photographs.
  • Keeps the daily log and change documentation current and marks up drawings as installed on the day the change is made.
  • Maintains meters, torque tools and arc rated PPE, confirms meter category rating and calibration, and tags damaged equipment out of service.
  • Cleans the work area and routes removed fixtures, lamps and ballasts to the correct recycling or disposal stream.

Qualifications

Required
  • Journeyman electrician license in the state of work, or a license the state will reciprocate, current and unrestricted.
  • Four years of commercial electrical experience including time on lighting retrofit or PV work.
  • Working knowledge of the electrical code in force locally, including the PV and interconnection articles.
  • Current NFPA 70E training, with the ability to select PPE by incident energy and run a correct lockout and tagout.
  • Valid driver license with an acceptable MVR; the role drives to multiple sites a week with tools and material.
  • Able to build from plans, single line diagrams, panel schedules and a written sequence of operations.
  • Able to lift 50 pounds, work from ladders and lifts, and work in electrical rooms, ceiling spaces and on roofs.
  • Own hand tools, a meter rated for the category of work, and arc rated PPE.
Preferred
  • Master electrician license, or qualification to hold the license on a permit.
  • NABCEP PV Installation Professional or documented PV commissioning experience.
  • Experience with a named networked lighting control platform and its commissioning software.
  • Switchgear or medium voltage experience and infrared thermography familiarity.
  • Experience with utility interconnection applications and rebate program documentation.
  • Aerial and scissor lift certification.
  • Ability to produce as-built markups and test reports that an engineer does not have to rewrite.

The line between these two columns is the one that costs you candidates. Everything in the preferred column that gets written into a posting as a requirement removes people who could do the job, and in a trade with a shortage that is a self-inflicted wound.

Credentials, and who verifies them

CredentialStatusVerify with
State journeyman electrician licenseRequiredState or municipal electrical board license lookup at hire and at each renewal
Master electrician licensePreferredState electrical board license lookup
NFPA 70E electrical safety trainingRequiredTraining certificate on file, refreshed on the required cycle
OSHA 10 or 30 construction cardRequiredTraining provider card and DOL outreach verification
NABCEP PV Installation ProfessionalPreferredNABCEP certificant registry
Aerial and scissor lift operator certificationWhere the state requires itTraining records plus employer evaluation per OSHA and ANSI

Verify before an offer rather than after. A credential taken on trust at offer is the most expensive line on this page. We track LED & solar licensing in 39 states; which of them applies depends on where the work is, not where the company is.

Physical demands

ActivityFrequency
Standing and walking on concrete, roofs and uneven site surfacesConstant (over 2/3 of shift)
Working overhead with arms raised to install raceway, fixtures and supportsFrequent (1/3 to 2/3 of shift)
Climbing and working from ladders, scissor lifts and boom liftsFrequent (1/3 to 2/3 of shift)
Lifting and carrying up to 50 pounds and team lifting gear and large fixturesFrequent (1/3 to 2/3 of shift)
Kneeling and crouching in tight electrical rooms and ceiling spacesFrequent (1/3 to 2/3 of shift)
Repetitive gripping, bending conduit and torquing terminationsFrequent (1/3 to 2/3 of shift)
Fine motor work and color discrimination on conductor insulation and control wiringFrequent (1/3 to 2/3 of shift)
Hand and arm vibration from hammer drills, benders and sawsOccasional (under 1/3 of shift)
Working outdoors and on hot roofs with PV equipmentOccasional (under 1/3 of shift)
Driving between job sites with tools and materialOccasional (under 1/3 of shift)
Wearing arc rated PPE including hood and face shield for energized tasksOccasional (under 1/3 of shift)
Working at height above six feet with fall protectionOccasional (under 1/3 of shift)

This is the section a reasonable accommodation decision actually turns on, which is why it is role specific rather than copied across a trade. An estimator sits and walks sites; a screed operator stands beside hot asphalt all day.

Work environment

Work moves between occupied commercial interiors, electrical and inverter rooms, warehouses worked from high lifts, parking lots and roofs. Much of the lighting work runs after hours or on second shift so tenants are not disturbed. Hazards include shock and arc flash, falls from lifts and ladders, ceiling dust, lamp breakage and mercury handling, hot roof surfaces and construction traffic. Coordination with building staff and other trades is constant.

Tools and equipment

The company provides benders, hydraulic and knockout tools, pullers, torque tools, category rated meters and testers, an infrared camera, lifts, commissioning software and licenses, arc rated PPE and the service truck. The electrician owns hand tools, a personal meter, drivers, strippers, levels, work boots and basic PPE.

How performance is measured

MeasureWhat it captures
Fixtures, circuits or kilowatts completed per dayInstall rate against the estimate for the scope and the site conditions
First time inspection pass rateShare of inspections and utility sign-offs passed without a correction notice
Callbacks and warranty returnsReturns for control programming, failed terminations or wrong fixture or driver selection
Commissioning completeness at turnoverWhether every control zone and inverter has a documented functional test before the job is called done
Closeout acceptanceUtility, rebate and owner documentation packages accepted on first submission
Labor hours against estimateActual hours charged versus estimated hours on assigned scopes
Safety recordRecordables, energized work incidents, and 70E and lockout compliance observed on audit

These are the same measures the annual review for this role is built on, so the document you hire against and the document you rate against are measuring one thing.

Reading a resume for this seat

What separates a strong Electrician (LED & Solar) from a plausible one, on paper and in the first ten minutes of a call:

  • Electrical licence current for the jurisdiction, stated without hedging
  • Has done an interconnection and dealt with the utility, not just the inverter
  • Lighting controls described as commissioning work rather than device installation

Screen for it: 3 questions and what a strong answer contains

A job description tells you what you need. These tell you whether the person in front of you has it. Each one comes with what a strong answer contains, because an interviewer who does not know that is persuaded by fluency, which is exactly what the question was supposed to see past.

Walk me through an interconnection from application to permission to operate.

What a strong answer contains

Describes the real sequence: the utility application with the single line and equipment specifications, their study and the interconnection agreement, the building permit and plan review, construction, the jurisdiction's inspection and sign-off, then the utility's witness test or meter change, and only then permission to operate. Knows the system cannot be energised before that and what the penalties are. Knows where the time actually goes in their utility.

Follow up with: Which step in that sequence takes the longest in your area?

How do you size conductors and overcurrent protection on a PV circuit?

What a strong answer contains

Works from the module and inverter ratings through the code's required factors rather than from the nameplate alone: the continuous current adjustment for PV source circuits, then temperature and conduit fill derating for a conductor on a hot roof, and checks the result against the overcurrent device and the terminal temperature rating. Checks voltage drop separately. Knows rooftop ambient adders are the step most often skipped.

Follow up with: What do people most often forget when sizing a conductor on a roof?

A networked lighting control system is not holding its schedule. How do you commission it?

What a strong answer contains

Separates the layers before touching settings: is it the time source, the network, the controller, or the individual devices? Checks the clock and whether it has a reliable time reference and a daylight saving rule, whether devices are actually joined and reporting, and whether somebody has overridden locally. Commissions by zone with the owner watching, documents the programming, and hands over how to change it without calling them.

Follow up with: What is the most common reason a lighting schedule drifts?

The mistake this seat invites

Treating retrofit work as device swapping. The licensed electrical scope, the interconnection and the controls commissioning are where the job succeeds or stalls.

How long this takes to fill

We publish no LED & solar median of our own yet, so this is the all-trades figure: My Trade Talent's median commercial trades hire took 21 days across 94 searches closed in 2026 year to date, counted as calendar days from our first contact with the candidate to the hire.

Worth writing on the requisition before you post it. The cost of the vacancy runs from the day the seat empties, not from the day you start looking, and the calculator will put a number on it for your billing rate.

Questions employers ask about this role

What does an Electrician (LED & Solar) do?

Performs the licensed electrical work on commercial lighting retrofit and solar projects: service and panel work, conductor sizing and raceway runs, inverter and disconnect installation, utility interconnection, and the control and sensor work that makes a lighting job meet its specification. This seat also carries the end of the job, meaning testing, commissioning, the inspection walkthrough and the utility or rebate sign-off, which is where the paperwork and the payment both live. The full description below lists 15 essential duties in trade terms, with physical demands and frequencies.

What qualifications does an Electrician (LED & Solar) need?

8 requirements are written as non-negotiable for this seat. The first 3: Journeyman electrician license in the state of work, or a license the state will reciprocate, current and unrestricted; Four years of commercial electrical experience including time on lighting retrofit or PV work; Working knowledge of the electrical code in force locally, including the PV and interconnection articles. A further 7 qualifications are preferred rather than required, which is the distinction that decides whether a good candidate gets screened out by your own posting.

What credentials should I verify before making an offer to an Electrician (LED & Solar)?

4 credentials on this role are either required outright or required where the state requires it: State journeyman electrician license, NFPA 70E electrical safety training, OSHA 10 or 30 construction card and Aerial and scissor lift operator certification. Each one has a named place to verify it in the table below. Verify before the offer rather than after; a credential taken on trust at offer is the most expensive line in a job description.

Is an Electrician (LED & Solar) exempt or non-exempt?

Non-exempt — confirm with counsel. FLSA status turns on the duties actually performed rather than the job title, and the duties for this seat are listed below so a classification decision has something to rest on. We are not lawyers and the note here is a starting point for counsel, not a determination.

What should an Electrician (LED & Solar) be paid?

$42,640 to $108,510. Federal figures: BLS Occupational Employment and Wage Statistics, May 2025, national, SOC 47-2111. The range is the 10th to 90th percentile and the median is $63,190. It is not adjusted for experience or region, and it is not a My Trade Talent band.

How long does it take to hire an Electrician (LED & Solar)?

We publish no LED & solar median of our own yet, so this is the all-trades figure: My Trade Talent's median commercial trades hire took 21 days across 94 searches closed in 2026 year to date, counted as calendar days from our first contact with the candidate to the hire.

What is the most common hiring mistake in this seat?

Treating retrofit work as device swapping. The licensed electrical scope, the interconnection and the controls commissioning are where the job succeeds or stalls.

Trade Talk A monthly hiring brief for commercial trades employers

What changed in your trade this month, and what to do about it.

One email a month, and only one. We write a separate issue for every trade we recruit in, so you get yours - not a round-up with your trade buried in paragraph nine. Every issue is written for the person actually doing the hiring.

  • Where wages moved in your trade, by market, and what that does to your next offer
  • How long roles like yours are taking to fill, and where it is getting worse
  • Interview and screening tactics that are landing candidates this month
  • What contractors competing for the same people are doing differently

Built on federal wage data, our own closed searches, and what we hear on the desk every week. Written for employers, not candidates. No pitch, no filler, one click to leave.

Pick your trade. That is the one issue you get, once a month.

One email a month. Your trade and your address, nothing else - we do not sell either, and you can unsubscribe from the bottom of any issue. Read this month's issue for your trade first →