HVAC Controls Technician (BAS / Niagara) Job Description
HVAC & Mechanical
Programs, commissions and troubleshoots building automation systems on commercial mechanical projects and service accounts. The work runs from pulling and terminating controls wiring and mounting devices, through building Niagara or equivalent graphics, schedules, alarms and trend logs, to point-to-point checkout and sequence-of-operations testing against the engineer's design intent. The technician is the last person between a sequence on paper and a building that actually runs it.
What this seat pays
My Trade Talent mid-experience band, built from our own engagement history. Experience and region move it; the salary calculator applies both.
Pay, location and the date prepared are blank in the Word version on purpose. They depend on your market and your margins, and a template that guesses at them is worse than one that leaves them to you. The figure above is here so the guess is at least anchored.
The seat
| Reports to | Controls Manager |
| Direct reports | None (may direct a controls installer or apprentice) |
| FLSA status | Non-exempt — confirm with counsel |
| Trade | HVAC & Mechanical |
| Pay band | $75,000 to $110,000 — My Trade Talent band |
Where the role goes next. Controls technicians move to commissioning agent, controls project manager, or independent integrator - the last of which is why they are hard to keep.
Essential duties (15)
- Pull, land and label low voltage controls wiring to sensors, actuators, VFDs and end devices, and dress panels so the next technician can follow them.
- Mount and wire control panels, install controllers, transformers, relays and network devices, and terminate shielded communication trunks with correct grounding.
- Program controllers in Niagara, the Tridium workbench or the manufacturer's tool, building logic to the engineer's sequence of operations rather than a generic template.
- Build operator graphics with live point values, setpoint adjustment and navigation an in-house building engineer can use without training.
- Configure schedules, holiday calendars, optimal start, setpoint resets and alarm classes with meaningful priorities and routing.
- Set up trend logs and histories on the points that matter for troubleshooting and for the owner's energy reporting.
- Integrate third party equipment over BACnet MS/TP, BACnet IP, Modbus or LonWorks, including addressing, device instance management and point mapping.
- Perform point-to-point checkout and document each point as commanded, read back and verified in the field.
- Run sequence-of-operations testing with the commissioning agent, including economizer changeover, freeze protection, pressure resets and failure modes.
- Troubleshoot network, controller and device failures on existing sites, including comm loss, failed sensors, hunting loops and overrides left behind by others.
- Tune control loops so valves and dampers hold setpoint without hunting, and clear every manual override before leaving a site.
- Produce and update as-built controls drawings, point lists, IP and device addressing schedules, and a written record of logic changes.
- Train the owner's maintenance staff on the front end, hand over logins and license files, and record the training date and attendees.
- Record labor daily against the project cost code or the service work order, and flag out-of-scope work for change order capture.
- Maintain the controls laptop, software versions, licensing and a backup copy of every site database.
Qualifications
- Three or more years programming and commissioning commercial building automation systems.
- Working competence in Niagara AX or N4, including station backup, hierarchy and tagging, or an equivalent platform such as Metasys, Desigo or WebCTRL.
- Able to read a sequence of operations, a control drawing and a point list and build the system from them without being handed the logic.
- Able to terminate and troubleshoot low voltage and 24 volt controls wiring and take readings safely around line voltage and VFDs.
- Working knowledge of BACnet MS/TP and BACnet IP, including addressing and troubleshooting a trunk with a meter and a protocol analyzer.
- Able to work from ladders and lifts, above ceilings and in mechanical rooms, and to lift 40 pounds.
- Valid driver's license and an insurable driving record.
- OSHA 10 within 30 days of hire, or willingness to obtain it.
- Current Tridium Niagara 4 certification.
- Experience as the controls contractor on a project with a third party commissioning agent and a formal functional test script.
- Familiarity with ASHRAE Guideline 36 sequences.
- State low voltage or limited energy license where the state issues one.
- Experience integrating chiller plants, boiler plants and VRF systems over native protocols.
- Scripting or database skill — Niagara program blocks, Python or SQL for reporting.
- Certified Energy Manager or a building commissioning credential.
The line between these two columns is the one that costs you candidates. Everything in the preferred column that gets written into a posting as a requirement removes people who could do the job, and in a trade with a shortage that is a self-inflicted wound.
Credentials, and who verifies them
| Credential | Status | Verify with |
|---|---|---|
| Tridium Niagara 4 certification | Preferred | Tridium certificate with certification date on file |
| State low voltage or limited energy license | Where the state requires it | State licensing board license lookup |
| EPA Section 608 Universal | Preferred | Certifying organization card |
| OSHA 10 or OSHA 30 construction | Required | Training provider card and DOL card number |
| NFPA 70E electrical safety training | Preferred | Training provider record, refreshed every three years |
| Valid driver's license | Required | Motor vehicle record run through the company insurer |
Verify before an offer rather than after. A credential taken on trust at offer is the most expensive line on this page. We track HVAC & mechanical licensing in 38 states; which of them applies depends on where the work is, not where the company is.
Physical demands
| Activity | Frequency |
|---|---|
| Sitting with a laptop in a mechanical room, panel room or job trailer | Frequent (1/3 to 2/3 of shift) |
| Standing and walking a building to chase points and devices | Frequent (1/3 to 2/3 of shift) |
| Climbing ladders and working from scissor lifts to reach ceiling devices | Frequent (1/3 to 2/3 of shift) |
| Kneeling, crouching and reaching overhead above the ceiling grid | Frequent (1/3 to 2/3 of shift) |
| Fine motor work terminating small gauge wire and setting dip switches | Frequent (1/3 to 2/3 of shift) |
| Reading small print on drawings, nameplates and device labels | Constant (over 2/3 of shift) |
| Lifting and carrying up to 40 pounds of panels, tools and wire | Occasional (under 1/3 of shift) |
| Working on rooftops and inside outdoor air handling equipment | Occasional (under 1/3 of shift) |
| Working near energized line voltage, VFDs and motor starters | Occasional (under 1/3 of shift) |
| Working in confined ceiling spaces, plenums and shafts | Occasional (under 1/3 of shift) |
| Driving between sites and the office | Occasional (under 1/3 of shift) |
| Lifting over 50 pounds | Rarely |
This is the section a reasonable accommodation decision actually turns on, which is why it is role specific rather than copied across a trade. An estimator sits and walks sites; a screed operator stands beside hot asphalt all day.
Work environment
Split between mechanical rooms, spaces above ceilings, panel and IT rooms, rooftop equipment and a laptop on a table in the job trailer or the owner's engineering office. Sites range from unfinished construction with dust and open penetrations to occupied hospitals, labs and offices where access and noise are restricted. Hazards include energized panels, arc flash near VFDs and starters, falls from lifts and ladders, and rotating equipment during functional testing. Night and weekend test windows are common.
Tools and equipment
The company provides the laptop, Niagara and vendor software licenses, protocol analyzer, multimeter, termination tools, label printer, ladders, lifts and all PPE other than boots. The technician is expected to own basic hand tools, screwdrivers and nut drivers, a pocket meter and steel toe boots, and to keep the company laptop and site backups secure.
How performance is measured
| Measure | What it captures |
|---|---|
| Point-to-point checkout completion on the first pass | How many points verify without a return trip |
| Functional test items failed during commissioning | Logic and wiring errors the commissioning agent finds against the sequence |
| Warranty and callback hours on systems the technician programmed | Hunting loops, nuisance alarms and overrides left behind after handover |
| Controls labor hours against estimate by project | Whether programming and checkout hold the hours the job was sold at |
| As-built documentation and station backups delivered at closeout | Whether the next technician can pick the site up cold |
| Nuisance alarm volume on handed-over sites | Alarm classes and limits set so the owner is not ignoring the front end |
| First-visit resolution on BAS service calls | Troubleshooting depth on systems the technician did not build |
These are the same measures the annual review for this role is built on, so the document you hire against and the document you rate against are measuring one thing.
Reading a resume for this seat
What separates a strong HVAC Controls Technician (BAS / Niagara) from a plausible one, on paper and in the first ten minutes of a call:
- Platform experience named specifically: Niagara, Metasys, Desigo, Distech, Delta. The platforms are not interchangeable
- Can read a sequence of operations and say where it will fail in practice
- Has integrated across protocols - BACnet MS/TP, IP, Modbus - rather than staying inside one vendor
Screen for it: 3 questions and what a strong answer contains
A job description tells you what you need. These tell you whether the person in front of you has it. Each one comes with what a strong answer contains, because an interviewer who does not know that is persuaded by fluency, which is exactly what the question was supposed to see past.
Give me a sequence of operations you found wrong during commissioning, and what you changed.
What a strong answer containsA specific sequence, not a general complaint. Simultaneous heating and cooling, a static reset never implemented, an economizer high limit set as fixed dry bulb where differential was specified, a sequence copied from a different unit. Crucially, says how the change was agreed and recorded with the engineer rather than quietly corrected in the field.
Follow up with: Who approved the change, and where is it written down now?
How do you troubleshoot a BACnet MS/TP trunk where one device drops intermittently?
What a strong answer containsTreats it as a wiring and signalling problem before a device problem. Daisy chain with no stars or spurs, termination at the two ends only, bias, shield grounded at one end, duplicate MAC addresses, baud and max-master mismatches, and noise from VFDs or ballasts running alongside the cable. Segments the trunk to isolate rather than swapping the device first.
Follow up with: How would you prove it is the wiring and not the controller?
When would you use a Niagara JACE rather than putting everything on the supervisor?
What a strong answer containsControl logic belongs at the edge. A JACE for protocol integration and for sequences that must keep running when the network or the supervisor is down; the supervisor for aggregation, global graphics, history and reporting across sites. Says plainly that a building whose control stops when a server reboots has been designed wrong.
Follow up with: What happens in the building if the supervisor goes offline for a day?
The mistake this seat invites
Screening this seat as an HVAC role. The scarce skill is integration and programming, and the strongest candidates often come from controls contractors or systems integrators rather than mechanical ones.
How long this takes to fill
My Trade Talent's median HVAC & mechanical hire took 15 days across 36 searches closed in 2026 year to date, counted as calendar days from our first contact with the candidate to the hire.
Worth writing on the requisition before you post it. The cost of the vacancy runs from the day the seat empties, not from the day you start looking, and the calculator will put a number on it for your billing rate.
Questions employers ask about this role
What does an HVAC Controls Technician (BAS / Niagara) do?
Programs, commissions and troubleshoots building automation systems on commercial mechanical projects and service accounts. The work runs from pulling and terminating controls wiring and mounting devices, through building Niagara or equivalent graphics, schedules, alarms and trend logs, to point-to-point checkout and sequence-of-operations testing against the engineer's design intent. The technician is the last person between a sequence on paper and a building that actually runs it. The full description below lists 15 essential duties in trade terms, with physical demands and frequencies.
What qualifications does an HVAC Controls Technician (BAS / Niagara) need?
8 requirements are written as non-negotiable for this seat. The first 3: Three or more years programming and commissioning commercial building automation systems; Working competence in Niagara AX or N4, including station backup, hierarchy and tagging, or an equivalent platform such as Metasys, Desigo or WebCTRL; Able to read a sequence of operations, a control drawing and a point list and build the system from them without being handed the logic. A further 7 qualifications are preferred rather than required, which is the distinction that decides whether a good candidate gets screened out by your own posting.
What credentials should I verify before making an offer to an HVAC Controls Technician (BAS / Niagara)?
3 credentials on this role are either required outright or required where the state requires it: State low voltage or limited energy license, OSHA 10 or OSHA 30 construction and Valid driver's license. Each one has a named place to verify it in the table below. Verify before the offer rather than after; a credential taken on trust at offer is the most expensive line in a job description.
Is an HVAC Controls Technician (BAS / Niagara) exempt or non-exempt?
Non-exempt — confirm with counsel. FLSA status turns on the duties actually performed rather than the job title, and the duties for this seat are listed below so a classification decision has something to rest on. We are not lawyers and the note here is a starting point for counsel, not a determination.
What should an HVAC Controls Technician (BAS / Niagara) be paid?
$75,000 to $110,000. My Trade Talent mid-experience band, built from our own engagement history. Experience and region move it; the salary calculator applies both.
How long does it take to hire an HVAC Controls Technician (BAS / Niagara)?
My Trade Talent's median HVAC & mechanical hire took 15 days across 36 searches closed in 2026 year to date, counted as calendar days from our first contact with the candidate to the hire.
What is the most common hiring mistake in this seat?
Screening this seat as an HVAC role. The scarce skill is integration and programming, and the strongest candidates often come from controls contractors or systems integrators rather than mechanical ones.
One time
Where should we send it?
Tell us who you are once and every document on this site downloads for you from then on, with no form in the way. We are a recruiting firm: someone may call about the roles you are hiring for.